GAS SECTION
7
7
TYPES OF GASES
The gases normally used may be
grouped, in view of their features, in
three families:
- L.P.G. (in cylinders) G30
- NATURAL GAS (methane) G20
- CITY GAS G110
INSTALLATION
The appliance is predisposed and adjust-
ed to operate with the gas indicated on
the specifications plate applied onto the
appliance.
If the appliance must be operated with a
gas different than that indicated on the
plate, it is necessary to execute the fol-
lowing operations:
– gas connection
– replacement of the injectors
– regulating of the minimum
Gas connection
The connection must be executed by
qualified technician according to the rele-
vant standard.
The fitting (fig. 7.1) is made up of:
1 elbow fitting “A
1 adapter “B” for natural or city gas
1 adapter “C” for L.P.G.
gaskets “D”, “E” and “F
The hob must be installed in a room with
adequate ventilation.
Gas connection for:
Natural gas G20 or city gas G110
Remove the adapter “C” using two
spanners.
Connect the cooking hob to the gas
net by a suitable rubber tube (inside
diameter 13 mm).
Make sure the tube is snugly fit at both
ends and use a standard tube clamp
(not supplied) to fasten it.
L.P.G. (in cylinders) G30
Fit up the adapter “C” to the adapter
B” interposing gasket “E”. Tighten
using two spanners.
Connect the cooking hob to the
cylinder pressure regulator by a
suitable rubber tube (inside diameter
8 mm).
Make sure the tube is snugly fit at both
ends and use a standard tube clamp
(not supplied) to fasten it.
24
D
B
F
A
E
C
Fig. 7.1