GAS SECTION
7
7
TYPES OF GASES
The gases normally used may be
grouped, in view of their features, in
three families:
- L.P.G. (in cylinders) G30
- NATURAL GAS (methane) G20
- CITY GAS G110
INSTALLATION
The appliance is predisposed and adjust-
ed to operate with the gas indicated on
the specifications plate applied onto the
appliance.
If the appliance must be operated with a
gas different than that indicated on the
plate, it is necessary to execute the fol-
lowing operations:
– gas connection
– replacement of the injectors
– regulating of the minimum
Gas connection
The connection must be executed by
qualified technician according to the rele-
vant standard.
The fitting (fig. 7.1) is made up of:
✓ 1 elbow fitting “A”
✓ 1 adapter “B” for natural or city gas
✓ 1 adapter “C” for L.P.G.
✓ gaskets “D”, “E” and “F”
The hob must be installed in a room with
adequate ventilation.
Gas connection for:
Natural gas G20 or city gas G110
✓ Remove the adapter “C” using two
spanners.
✓ Connect the cooking hob to the gas
net by a suitable rubber tube (inside
diameter 13 mm).
Make sure the tube is snugly fit at both
ends and use a standard tube clamp
(not supplied) to fasten it.
L.P.G. (in cylinders) G30
✓ Fit up the adapter “C” to the adapter
“B” interposing gasket “E”. Tighten
using two spanners.
✓ Connect the cooking hob to the
cylinder pressure regulator by a
suitable rubber tube (inside diameter
8 mm).
Make sure the tube is snugly fit at both
ends and use a standard tube clamp
(not supplied) to fasten it.
24
D
B
F
A
E
C
Fig. 7.1